DeHealthFoundation · UA

19 November 2026

The cold chain: why it breaks and what to do about it

The foundation delivers medical equipment and preparations to Ukraine, so the cold chain is not an abstraction for us. Here, in one place, is what actually fails most often, following the CDC guidance published in July 2026, and what is done when temperature goes out of range.

The cold chain is an unbroken sequence of storage and transport within a defined temperature range, from manufacturer to patient. The word unbroken is the operative one: the chain has no concept of partial compliance. A single episode undoes the result of every link before it.

Why you cannot see it

CDC guidance puts it without softening: once potency is lost, it cannot be restored. For refrigerated vaccines, a single exposure to freezing temperatures, 0°C or colder, can completely destroy potency.

And separately, on appearance. Vaccine appearance is not a reliable indicator that storage was correct: inactivated vaccines, even after exposure to freezing temperatures, may not appear frozen, so there is no visual sign of lost potency at all.

«Potency decreases every time a vaccine is exposed to improper conditions. Once lost, it cannot be restored.»
– CDC, Vaccine Storage and Handling Toolkit, July 2026

Cause one: the wrong refrigerator

The commonest cause is not a breakdown but an ordinary domestic appliance in the wrong role. CDC guidance forbids outright the use of dormitory- or bar-style combined refrigerator/freezer units for vaccine storage: single exterior door, evaporator in the freezer compartment. They pose a significant risk of freezing vaccines even when used temporarily.

A household-grade unit is permitted only as a last option and only for refrigerated vaccines. Vaccines are never stored in the freezer compartment of a household combination unit, because it has cold spots and temperature fluctuations. If frozen storage is needed, a separate stand-alone freezer is required.

Even in the refrigerator compartment, air circulating from the freezer can expose vaccines to freezing temperatures, so nothing goes on the top shelf directly under the cooling vent. In order of preference the guidance puts units conforming to NSF/ANSI Standard 456 first, then purpose-built vaccine storage units.

Cause two: a thermometer that cannot see the breach

The unit's thermostat does not show temperature: it is generally marked in levels of coldness rather than degrees. The only way to know the temperature is to measure it with a separate device. The thermostat itself is set to the factory or midpoint value, for example 5°C for refrigerators and -20°C for freezers, to reduce the risk of excursions.

The recommended device is a digital data logger. It records continuously and shows how long the unit was operating outside the allowed range, whereas a simple minimum/maximum thermometer shows two extremes with no duration. The active display goes outside the unit so temperatures can be read without opening the door.

What CDC does not recommend for this: alcohol or mercury thermometers, bimetal stem devices, devices made for food, chart recorders, infrared devices, and anything without a current valid Certificate of Calibration Testing. Devices sold in hardware stores are designed for household food storage and are not accurate enough; using them poses a significant risk of damaging vaccines.

Calibration testing is performed every two to three years, or on the manufacturer's schedule: devices drift over time.

The working ranges

CDC requires units to maintain these ranges at all times: refrigerators between 2°C and 8°C; freezers between -50°C and -15°C; ultra-cold freezers between -90°C and -60°C. The requirement for any specific product is always checked against the manufacturer's insert.

Cause three: power, transport and light

A facility's written procedures have to include emergency ones: a plan to monitor, pack and transport products in the event of equipment failure or a power outage. In Ukraine that is not a theoretical section, which is exactly why it has to be written in advance rather than improvised during an outage.

Light is its own category. Certain products, including mRNA vaccines and most influenza vaccines, lose potency when exposed to light. That is a breach no temperature chart will ever show.

And one more, mentioned less often: a temperature controller can cause a breach through interference rather than failure. In November 2026 five US federal agencies jointly warned about attacks on industrial refrigeration and cold chain systems, and healthcare stands alongside food in their list of sectors. We covered that separately.

What to do when temperature goes out of range

The sequence in the guidance is simple, and the order is the point. First: whoever hears the alarm or notices the excursion immediately notifies the vaccine coordinator or their supervisor. Second: affected products are labelled "DO NOT USE - TEMPERATURE EXCURSION", moved to correct storage conditions and placed in a separate container. They are not discarded.

Third: the event is documented - date and time, unit and room temperature, minimum and maximum over the period, who is filing the report, a description of what happened, how long the exposure lasted according to the data logger, an inventory of affected products with lot numbers, a list of everything else in the unit, and whether the unit had problems before.

The decision on usability is not the facility's to make. Products stored at inappropriate temperatures are not administered unless public health authorities or the manufacturer confirm they are safe and effective based on stability data. If such doses have already been given, they should generally be repeated.

Why we are writing this

Since February 2022 the foundation has delivered medical and humanitarian aid to Ukraine, and part of that cargo carries temperature requirements. The cold chain is the part of logistics where a mistake cannot be seen and cannot be corrected after the fact: a consignment either arrived usable or it did not, and the temperature log is the only place you find out.

So this is not advice. It is a statement of published requirements with links to the primary sources. Clinical decisions about any specific product follow the manufacturer's insert and a professional's judgement.